CFI plan apochromat series objective lenses for phase contrast microscopy. Correction for chromatic aberration has been improved and now extends across the entire visible spectrum to include the violet wavelength. High Numerical Apertures with longer working distances, comprehensive aberration correction, and superior flatness of field of view across 25mm make Nikon’s CFI Plan Apochromat series for phase contrast microscopy ideal for the most demanding research projects. These objectives can also be used effectively for DIC observation.
Download the brochure:
CFI60
The CFI Plan Apochromat VC series Objective Lenses are top performance objectives with perfect correction of chromatic aberrations in the visible light range and excellent resolution throughout the field of view. They are the perfect choice for multi-stained, fluorescence specimens and when using brightfield and DIC techniques. In addition to the correction range of the conventional Apochromat series (435-660nm), axial chromatic aberration has been corrected up to the violet range (405nm), making these objectives highly effective PA-GFP, as well as other photo-activation and photo-conversion proteins that activate at 405nm. CFI Plan Apochromat VC optics are an ideal choice for critical confocal work as well.
Download the brochure:
CFI60
Featuring exceptionally high transmission from the ultra-violet to the infra-red and flatness across the field of view, the CFI Plan Fluor series objective lenses are designed for incredible high contrast fluorescence observation and photomicrography. The performance and quality of Plan Fluor objectives make them a terrific choice as multipurpose objectives for brightfield, fluorescence, polarizing, and DIC observations.
Download the brochure:
CFI60
CFI plan fluor series objective lenses for phase contrast microscopy. These objectives are multi-purpose; they can be used for brightfield, fluorescence, phase contrast and for Nomarski DIC observations. They facilitate high-quality fluorescence observation and provide exceptionally detailed resolution of minute structures in phase contrast or DIC observation. The use of phase contrast to find the desired portion of the specimen before switching to fluorescence observation is an excellent way to minimize fluorescence photobleaching.
Download the brochure:
CFI60
CFI Super Fluor Series objective lenses provide the highest ultra-violet transmission, exceptionally high NA’s, and terrific chromatic correction. Thanks to outstanding transmission below 340nm, Super Fluor objectives are the ideal choice for fluorochromes like indo-1, fura-2, and fluo-3. Also, these objectives have improved signal-to-noise (S/N) for short wavelengths, due to low auto-fluorescence materials, and have high N.A,, making the fluorescence images they produce significantly sharper and brighter. They are also a great choice for photo-activation of caged compounds.
Download the brochure:
CFI60
CFI Super Plan Fluor ELWD objectives are well suited for fluorescence observations, especially with inverted microscopes. Because of their superior optical design, these objectives can be used universally for all other observation techniques, including brightfield, phase contrast, and Nomarski DIC. As a result of the extra long working distances, and their universal capability for imaging modalities, CFI Super Plan Fluor ELWD lenses are the best choice for critical high content and high throughput microscopy.
Download the brochure:
CFI60
Download the brochure:
Awareness – Chemwell 2910
Download the brochure:
Awareness – ChroMate 4300
Andor’s expertise in scientific performance optimization has been harnessed once again. Clara has been designed to deliver the highest sensitivity performance achievable from an interline CCD camera
Based around the popular ICX285 sensor from Sony®, the Clara interline CCD is ideally suited to high-resolution cell microscopy and OEM applications. Andor’s proven UltraVac™ process, alongside close attention to thermal management, has resulted in deep air cooling to -55°C for elimination of darkcurrent, complementing a unique read noise of 2.4e- @ 1 MHz.
More dynamic events can be followed with outstanding quantitative stability via low noise 10 or 20 MHz readout modes, the data channeled through a trouble free USB 2.0 interface. Andor’s iCam technology enables market-leading acquisition efficiency through live cell microscopy softwares. The compact, robust design and accessible SDK, renders Clara interline CCD camera ideally suited to OEM integration.
Download the brochure:
Clara
Esco CelCulture CO2 incubators are widely used in scientific research to grow and maintain cell cultures. Typical fields of application include tissue engineering, in vitro fertilization, neuroscience, cancer research, stem cell research, regenerative medicine, and other mammalian cell research.
Sleek, reliable and intuitive, Esco CelCulture CO2 incubators provide all-rounded sample protection that brings your scientific dreams one step closer to reality.
The SLEE rotary microtome series 4062 is a precision manual modular system suitable for paraffin sections and research, plastic and industrial applications. A universal cassette system and varying accessories make the CUT 4062 simple to operate. The advanced accessory design enables easy specimen changes. Rapid knife change, knife movement and angle adjustment can be carried out and specimen supports can be changed without loss of the basic adjustment.
A knifeguard locks when in position for safety. The microtome safety lock is integrated into the hand wheel for convenience.
Download the brochure:
CUT 4062
The SLEE rotary microtome series 5062 is a semi-automatic modular system with exceptional precision suitable for paraffin sections and research, plastic and industrial applications. A universal cassette system and varying accessories make the CUT 5062 simple to operate. The advanced accessory design enables easy specimen changes. Rapid knife change, knife movement and angle adjustment can be carried out and specimen supports can be changed without loss of the basic adjustment. The semi-automatic unit offers additional advantages against the manual microtome whilst retaining all the essential features of this series.